MCH RF Frequency Counter,FC-3000 RF frequency counter, max. can test to 3.7GHz

MCH RF Frequency Counter,FC-3000 RF frequency counter, max. can test to 3.7GHz
Product Detailed
FC-3000 frequency counter: 1.Freq:max.3.7GHz 2.RPM measure function 3.EXT.FREQ standard input with 9digit LED display

MCH RF Frequency Counter,FC-3000 RF frequency counter,max.3.7GHz frequency:

Specificaitons:

                                    Model

Specifications

FC-3000

Display

9digit large LED display, overflow, gate time, mHz, Hz, kHz, MHz, nS, uS, mS,S, HOLD

Frequency measurement

Range

0.1Hz to 100MHz (A input), 80MHz to 3.7GHz (C input )

Gate time

0.01Sec, 0.1Sec, 1Sec, 10Sec

Resolution

1nHz to 10Hz

Accuracy

±Resolution  ±Time base Error ±Count

Input characteristics

Terminal

A,C

Sensitivity

A input; 20mVrms, C input: 30mVrms

Impedance

A input: 1Mohm, Less than 40pF, C input : 50ohm

Max. input voltage (

A input :250Vrms, C input: 3Vrms

Attenuator

A input: x1,x10

Low pass filter

A input: 100kHz, -3dB

Multi function for input A

Period

Rang :10mSec to 10 Sec

Resolution:1pSec to 1nSec depending on gate time and input signal

Accuracy: ±Resolution  ±trigger error ±1Count

Totalize

Range : 5Hz to 10MHz

Count capacity: 1 to 999999999 (Max.)

RPM

6 RPM t 900 X106RPM

Time base characteristics

Internal time bases

Frequency :100MHz TCO(TCXO; option)

Aging rate: less than X5 10-6/month

Temp. stability: less than 5x10-6 (0°C to +50°C)

Line voltage: less than 1x10-6 for 10% variation

Frequency standard output (

Frequency :10MHz

Amplitude :1.5Vp-p

Impedance: approx. 600ohm

External standard output

Frequency :10MHz

Amplitude :1.5Vrms to 5Vrms

Impedance: approx. 600ohm

Others

Power requirement

110/220VAC ±10%, 50/60Hz

Operating temperature

0-50°C (accuracy specified at 25±5°C)

Dimension

39*26*9cm

Weight

 *Specifications are subject to change without prior notice.